Product Datasheet
Component Heaters
Issued 19 Oct 2026
Flameproof Drum Heater
Flameproof Drum Heaters represent the pinnacle of safety-engineered heating technology specifically designed for hazardous industrial environments where explosive vapors, gases, or combustible dusts may be present. These advanced heating systems are meticulously engineered to meet the stringent requirements of ATEX (Atmosphères Explosibles) and IECEx (International Electrotechnical Commission Explosive) safety standards, ensuring completely safe operation in Zone 1 and Zone 2 classified areas without risk of ignition or explosion.
- Up to 200°C
- ATEX & IECEx Certified
- 0.5 kW to 4 kW

Technical Specifications
| Heating Band Material | Stainless Steel 316L with embedded resistance elements |
|---|---|
| Power Rating | 0.5 kW to 4 kW (custom ratings available) |
| Temperature Range | Ambient to 200°C (up to 300°C custom) |
| Voltage Rating | 110V AC, 240V AC, 415V AC (custom voltages) |
| Safety Certifications | ATEX Zone 1/21, IECEx, PESO certified |
| Protection Class | IP65/IP66 weatherproof rating |
| Enclosure Material | Cast aluminum or stainless steel flameproof housing |
| Temperature Control | Adjustable thermostat with ±2°C accuracy |
| Insulation Material | High-density mineral wool, flame-retardant |
| Drum Compatibility | 200L (55-gallon) standard, custom sizes available |
| Cold Resistance Tolerance | ≤3% |
| Heating Time | 2-4 hours (depending on material and ambient conditions) |
Construction
- Heating Band
- Premium flexible stainless steel heating band with embedded high-quality resistance elements for uniform heat distribution around drum circumference. Features corrosion-resistant construction and optimal thermal conductivity for efficient heating performance.
- Flameproof Junction Box
- ATEX and IECEx certified explosion-proof enclosure housing all electrical connections and control components. Constructed with cast aluminum or stainless steel with flame-path gaps to prevent ignition transmission to hazardous atmospheres.
- Safety Thermostat
- Precision adjustable thermostat with automatic thermal cut-off protection and over-temperature safety shutdown. Features explosion-proof construction with tamper-resistant settings for reliable temperature control in hazardous environments.
- Thermal Insulation Assembly
- High-density mineral wool insulation with flame-retardant properties to minimize heat loss and provide thermal protection. Designed for maximum energy efficiency while ensuring operator safety and meeting hazardous area requirements.
- Safety Control System
- Integrated safety monitoring system with earth leakage protection, emergency shutdown capability, and status indication. Features certified intrinsically safe circuits and fail-safe operation for maximum hazardous area safety.
Key Features
- ATEX and IECEx certified flameproof design for hazardous environments
- Explosion-proof construction prevents ignition in volatile atmospheres
- Uniform drum heating with superior temperature maintenance
- Robust stainless steel construction for corrosion resistance
- Easy installation and removal with portable design options
- Precision temperature control with automatic safety cut-off
- Energy-efficient operation with minimal heat loss
- Maintenance-free design for extended service life
- IP65/IP66 weatherproof rating for outdoor installations
- Multiple voltage configurations for global compatibility
Applications
- Chemical processing and storage facilities
- Petrochemical plants and refineries
- Oil viscosity control in hazardous storage areas
- Paint and coating manufacturing facilities
- Pharmaceutical production in classified zones
- Adhesive and solvent heating applications
- Food processing in explosive atmosphere areas
- Lubricant and wax heating systems
- Explosive material handling facilities
- Marine and offshore platform applications